Lab Master Ball Burst Tester

For measuring Burst Force, Burst Strength and Burst Index with 0.1 gram resolution and 0.02% accuracy.

The Lab Master Ball Burst Tester measures Burst Force, Burst Strength and Burst Index with 0.1 gram resolution and 0.02% accuracy.

Analyze penetration resistance (poke-through strength) of dry or wetted sample. Measure and control position with 0.1 μm resolution and 0.2 μm repeatability. Thousands of data points per test are used to generate force/distance curves that reveal material behaviour during test.

Applications
Tissue, Nonwovens, Paper

Standards
TAPPI T 570, ISO/FDIS 12625-9:2001 CEN TC 172 (Proposed European Standard)

Features

  • User-selectable contact pressure, position, rate of separation and duration of test
  • Display test results as numbers and curves
  • Configure for R&D analysis or one-touch automated process control
  • RS-232 output
  • Sample clamp included; pneumatic clamp optional
  • Includes Windows operating system and touch screen flat panel display in a compact, network ready unit
  • Innovative design (patent pending) maintains accuracy over changing loads and frequent use

Technical Data

Connections
Electrical: Auto-ranging Power Supply

  • 100-120 V nominal ±10%, 50/60 Hz
  • 220-240 V nominal -5% +10%, 50/60 Hz

Force and Range

  • Range & Resolution: 2270 gf x 0.1 gf
  • Measurement Accuracy: ±0.5 gf or 0.5% of reading
  • Control Accuracy: ±0.68 gf steady state
  • Force (tension and compression)
    • Maximum: ±2.3 kg ±5.0 lb
    • Other force ranges available
  • Resolution: 0.1 g (0.0002 lb)
  • Accuracy: ±0.5% of reading ±0.5 g (Exceeds the requirements of ISO 7500-1 Class 0.5)
  • Overload Rating: 150% (Other force ranges available)
  • Travel and Position (maximum): 160 mm (6.25 inches) (Varies, depending on attachment)
  • Position Resolution: 0.1 µm (0.00004 inches)
  • Position Repeatability: 0.2 µm (0.00008 inches)
  • Position Accuracy: ±1.0 µm ( ±0.0004 inches)
  • Position Accuracy (cumulative):   ±1.0 µm/60mm ( ±0.000017 inches/2.4 inches)

Speed

  • Range: 0.01 to 13 mm/sec (0.01 to 0.5 inches/sec)
  • Accuracy (Steady State) better than 0.05%
  • Data Acquisition Rate2 kHz

Dimensions

  • Throat Depth: 82 mm (3.3 inches)
  • Number of Repeat Cycles: As Required

Display

  • TFT flat panel touch screen300 mm (12 inch)

Physical Dimensions

  • Height: 880 mm (34.75 inches)
  • Width: 490 mm (19.25 inches)
  • Depth: 535 mm (21.00 inches)

Working Surface

  • Height: 290 mm (11.5 inches)
  • Weight: 50 kg (110 lbs)

Electrical Characteristics

  • Supply Voltage (universal) 100-240 VAC
  • Current (max.) 10 Amperes
  • Frequency: 50-60 Hz

Environmental Range

  • Temperature (operating): 5 °C to 35 °C40 °F to 95 °F
  • Temperature (storage): -20 °C to 55 °C-4 °F to 130 °F
  • Humidity (operating and storage): 10% to 85% Non-condensing